Operation Descriptions
1 Delay on Make - TD
Upon application of power, the time delay begins. At the end of the time delay, the load
is energized. Reset is accomplished by removal of power.
2 Delay on Break - TDB
Power is applied at all times. Upon closure of a normally open initiate switch, the load
energizes and remains energized. Once the initiate switch opens, the timing cycle begins.
At the completion of the time delay, the load de-energizes and the timer is ready for a
new timing cycle.
3 Recycle - TDR
Upon application of power, the load is energized and an "on" time delay begins.
At the completion of the "on" time delay, the load will de-energize and an
"off" time delay begins. The timer will continue to cycle until the power is
removed.
4 Interval - TDI
Upon application of power, the output is energized and a time delay begins. At the
completion of the time delay, the load de-energizes. Reset is accomplished by removal of
power.
Specifications |
| Operating Voltage |
12-24, 115 VDC or VAC |
| Control Initiate Voltage
(Isolated) |
18 to 130 Volts |
| Supply Voltage Tolerance |
+/- 10% |
| Input Frequency |
50/60 Hz |
| Time Delay Range |
0.1 Second to 12 Hours |
| Repeatability Error |
+/- 0.5% Typical |
| Operating Temperature Range |
-40 degrees to 40 degrees C |
| Storage Temperature Range |
-40 degreees to 85 degrees C |
| Recycle Time |
Delay On = Delay Off |
| Transient Protection |
2 X Rated Input For 10 mS or 1500
Volts for 150 microseconds |
| Output Rating |
1.5 Amps DC - 4 Amps AC, 1/4 HP |
| Mechanical Mounting Termination |
One #8 or #10 screw |
| Termination |
3/16" or 1/4" Quick
Disconnects |
For Application
Assistance, Quotation, Product Specifications, or Custom Design Call RBE Electronics'
Sales Department at 1-800-541-4056