Applications |
Agricultural Equipment - Heavy
Construction Equipment - Generators Light Construction Equipment - Automotive - Semi
Tractors |
Operation
The FLD 150 Fluid Control operates by detecting the electrical resistance of fluids.
The FLD 150 is designed to detect the presence of moisture in the fuel/water separator and
low coolant level in engines.
The FLD 150 provides dual operation functions. If moisture is detected in the
fuel/water separator, the output will cycle and alarm. If coolant is detected as being
low, the output of the FLD 150 will alarm continuously.
Specifications |
| Operating Voltage |
12-24 VDC |
| Output Current Sinking |
300 mA |
| Supply Current |
<100 mA |
| Operating Temperature |
-40 Degrees C to 80 Degrees C |
| Storage Temperature |
-55 Degrees C to 80 Degrees C |
| Probe Sensing Distance |
Up to 25 Feet |
| Maximum Probe Sensing Current |
560 uA |
| Coolant Sensing Sensitivity |
<50,000 Ohms |
| Fuel/Water Sensing Sensitivity |
<18,000 Ohms |
| Probe Input Frequency Range |
1 KHz to 3 KHz |
| Humidity |
100% Condensing |
| Packaging |
Epoxy Potted, Plastic Case |
| Terminations |
AWG 18 Wire |
For Application Assistance,
Quotation, Product Specifications,
or Custom Design Call 1-800-541-4056